LED Drivers
All Rebel LEDs must be powered using a current regulating driver. The driver you select will depend on the needed lumens output, the number of LEDs being powered, the input voltage source, and the required drive current. Our Knowledgebase offers several helpful articles about powering LEDs.
Click the Drivers tab on this page for a list of compatible drivers.
Thermal Management
The SW-03-B3 LED module requires careful attention to mounting and cooling to ensure that the junction temperature of the LEDs is kept well below the maximum rating specified in the Lumileds datasheet. Detailed instructions for measuring the LED junction temperature can be found in the LED module datasheet. We recommend that the module be mounted to an aluminum or copper finned heatsink exposed to open air for optimal cooling. The module can be mounted to the heat sink in one of two ways:
- 20mm star pressure sensitive, thermally conductive tape (Recommended)
- Arctic Silver thermally conductive adhesive
Before fastening the module to the heat sink, ensure the module and heatsink surfaces are flat and clean for optimal heat transfer. Mechanical fasteners are not recommended for this module. The bottom of the LED module is electrically neutral, so it is unnecessary to electrically isolate the base from the cooling surface.
Click the Cooling tab on this page for a list of compatible heatsinks and supplies.
Optics
Rebel LEDs include a silicone lens to protect the LED chip and extract the maximum amount of light. This optic is quite delicate, and care must be taken to avoid touching or applying any force against it as it can be easily dislodged from the LED. Most applications use a secondary optic positioned above the LED to further shape and focus the light output. The SW-03 module has been designed to accommodate a variety of optics from Carclo and Ledil.
Click the Optics tab on this page for a list of compatible optics.
Optional IDC Connectors
If you order the optional IDC connectors, a punch-down tool will be included with the module at no charge. This tool can be used with any standard 1/4″ hex-bit screwdriver handle. Connectors are available for 22, 24, and 26 AWG solid or stranded wire. The connectors wire gauge will be printed on the top of the LED module.
LED Binning
We offer binned versions of this LED module when ordered in reel quantities (334 pieces). Please contact us for binning details before you order
For orders less than 334 pieces, binning information is not available. In these cases, modules are assembled from cut strips of LEDs, where individual bin numbers are not tracked. You can learn more about LED binning here.
Stock
This LED module is built when ordered. There are no minimum order requirements.
Please contact us for production lead times for orders above 100 pieces.
LED Color | Blue |
Recommended Operating Current | 350 mA |
Maximum Rated Drive Current | 1000 mA |
Maximum Pulse Current | 1000 mA |
Typical Forward Voltage | 8.85 Vf |
Maximum Forward Voltage | 10.53 Vf |
Lumens @ 350 mA | 105 lm |
Lumens @ 700 mA | 168 lm |
Wavelength Range | 460 to 485 K |
Beam Angle | 125° |
Thermal Resistance | 10.4 °C/W |
Maximum Recommended Junction Temp | 150 °C |
Operating Temperature Range | -40 to 135 °C |
Dimensions (L x W x H) | 21.5 x 21.5 x 3.1 mm |
Weight | 1.4 g |
Refer to the product datasheets for complete specifications. |
---|
A current-regulating LED driver is required between the power supply and the LED module to ensure that the LED is not powered above its maximum current rating. You can learn more about powering high-power LED modules here.
All drivers listed here are 100% compatible with the SW-03-B3 LED module. The driver you select will depend on your specific requirements.
Product Information | Stock | Price | hf:att:pa_output-current | hf:att:pa_connection | hf:att:pa_dimming |
---|
High-power LEDs include a primary optic for protection and light optimization. However, a secondary optic is often essential for better focus and light distribution.
All the optics except the Polymer 15 mm optic are 100% compatible with the SW-03-B3 LED module. Polymer 15 mm optics cannot be used if you select the connector option.
Note: The optics listed here may not be ideal for ultraviolet or infrared LEDs. You will need to test the optic for your specific application.
Product Information | Stock | Price | hf:att:pa_beam-type | hf:att:pa_mounting |
---|
To maximize life and reliability, a heatsink or alternate method of cooling is required to ensure that the junction temperature of the LED is kept well below its maximum temperature rating.
Refer to our Thermal Management articles for assistance selecting an appropriate heatsink from the available options here.
Product Information | Stock | Price | hf:att:pa_length-hs | hf:att:pa_width-hs | hf:att:pa_height-hs | hf:att:pa_cw-filter | hf:att:pa_fin-type |
---|
RoHS Status | RoHS 3 Compliant |
REACH Status | REACH Uneffected |
Conflict Minerals Report | CMRT Rev 6.22 |
Proposition 65 Statement | Proposition 65 |
PFAS Declaration | PFAS Declaration |
ECCN | EAR99 |
HTS | 8543.70.71.00 |
Country of Origin | CA |
LED Drivers
All Rebel LEDs must be powered using a current regulating driver. The driver you select will depend on the needed lumens output, the number of LEDs being powered, the input voltage source, and the required drive current. Our Knowledgebase offers several helpful articles about powering LEDs.
Click the Drivers tab on this page for a list of compatible drivers.
Thermal Management
The SW-03-B3 LED module requires careful attention to mounting and cooling to ensure that the junction temperature of the LEDs is kept well below the maximum rating specified in the Lumileds datasheet. Detailed instructions for measuring the LED junction temperature can be found in the LED module datasheet. We recommend that the module be mounted to an aluminum or copper finned heatsink exposed to open air for optimal cooling. The module can be mounted to the heat sink in one of two ways:
- 20mm star pressure sensitive, thermally conductive tape (Recommended)
- Arctic Silver thermally conductive adhesive
Before fastening the module to the heat sink, ensure the module and heatsink surfaces are flat and clean for optimal heat transfer. Mechanical fasteners are not recommended for this module. The bottom of the LED module is electrically neutral, so it is unnecessary to electrically isolate the base from the cooling surface.
Click the Cooling tab on this page for a list of compatible heatsinks and supplies.
Optics
Rebel LEDs include a silicone lens to protect the LED chip and extract the maximum amount of light. This optic is quite delicate, and care must be taken to avoid touching or applying any force against it as it can be easily dislodged from the LED. Most applications use a secondary optic positioned above the LED to further shape and focus the light output. The SW-03 module has been designed to accommodate a variety of optics from Carclo and Ledil.
Click the Optics tab on this page for a list of compatible optics.
Optional IDC Connectors
If you order the optional IDC connectors, a punch-down tool will be included with the module at no charge. This tool can be used with any standard 1/4″ hex-bit screwdriver handle. Connectors are available for 22, 24, and 26 AWG solid or stranded wire. The connectors wire gauge will be printed on the top of the LED module.
LED Binning
We offer binned versions of this LED module when ordered in reel quantities (334 pieces). Please contact us for binning details before you order
For orders less than 334 pieces, binning information is not available. In these cases, modules are assembled from cut strips of LEDs, where individual bin numbers are not tracked. You can learn more about LED binning here.
Stock
This LED module is built when ordered. There are no minimum order requirements.
Please contact us for production lead times for orders above 100 pieces.
LED Color | Blue |
Recommended Operating Current | 350 mA |
Maximum Rated Drive Current | 1000 mA |
Maximum Pulse Current | 1000 mA |
Typical Forward Voltage | 8.85 Vf |
Maximum Forward Voltage | 10.53 Vf |
Lumens @ 350 mA | 105 lm |
Lumens @ 700 mA | 168 lm |
Wavelength Range | 460 to 485 K |
Beam Angle | 125° |
Thermal Resistance | 10.4 °C/W |
Maximum Recommended Junction Temp | 150 °C |
Operating Temperature Range | -40 to 135 °C |
Dimensions (L x W x H) | 21.5 x 21.5 x 3.1 mm |
Weight | 1.4 g |
Refer to the product datasheets for complete specifications. |
---|
A current-regulating LED driver is required between the power supply and the LED module to ensure that the LED is not powered above its maximum current rating. You can learn more about powering high-power LED modules here.
All drivers listed here are 100% compatible with the SW-03-B3 LED module. The driver you select will depend on your specific requirements.
Product Information | Stock | Price | hf:att:pa_output-current | hf:att:pa_connection | hf:att:pa_dimming |
---|
High-power LEDs include a primary optic for protection and light optimization. However, a secondary optic is often essential for better focus and light distribution.
All the optics listed here are 100% compatible with the SW-03-B3 LED module.
Product Information | Stock | Price | hf:att:pa_beam-type | hf:att:pa_mounting |
---|
To maximize life and reliability, a heatsink or alternate method of cooling is required to ensure that the junction temperature of the LED is kept well below its maximum temperature rating.
Refer to our Thermal Management articles for assistance selecting an appropriate heatsink from the available options here.
Product Information | Stock | Price | hf:att:pa_length-hs | hf:att:pa_width-hs | hf:att:pa_height-hs | hf:att:pa_cw-filter | hf:att:pa_fin-type |
---|
RoHS Status | RoHS 3 Compliant |
REACH Status | REACH Uneffected |
Conflict Minerals Report | CMRT Rev 6.22 |
Proposition 65 Statement | Proposition 65 |
PFAS Declaration | PFAS Declaration |
ECCN | EAR99 |
HTS | 8543.70.71.00 |
Country of Origin | CA |